APPROVED DOCUMENT K

 0    58 词汇卡    sim
下载mp3 打印 检查自己
 
问题 答案
approved
What is a approved Document?
开始学习
zatwierdzony
Building Regulations
开始学习
Przepisy budowlane
protection from impact
Protection from falling, collision and impact
开始学习
Ochrona przed uderzeniami
impact
The definition of impact is one thing crashing into or having an affect on another.
开始学习
wpływ / zderzenie
ladder
开始学习
drabina
loading bays
开始学习
strefa załadunku
Vehicle barriers
开始学习
Bariery pojazdów
glazing
开始学习
szyby
provisions
Additional provisions for glazing in buildings other than dwellings.
开始学习
Przepisy
dwellings
Additional provisions for glazing in buildings other than dwellings.
开始学习
mieszkaniowe
trapping by doors
trap.
开始学习
uwięzienie przez drzwi
pułapka
compliance with the law
开始学习
zgodność z prawem
workmanship
开始学习
jakość wykonania
Handrail
开始学习
Poręcz
helical stair
helical stair = spiral stair
开始学习
spiralny schody
noising
开始学习
nosek schodów
stair tread
开始学习
stopnica
pitch
开始学习
kąt nachylenia
rise
开始学习
wysokość stopnia
riser
开始学习
wysokość stopnia
landing
The width and length of every landing should be at least as great as the smallest width of the flight. (minimum 1 m)
开始学习
podest / spocznik
staircase
开始学习
klatka schodowa
stair enclosure
开始学习
klatka schodowa
flight of stairs
开始学习
bieg schodów
straight flight stairs
开始学习
Schody jednobiegowe proste
dog-legged stairs
开始学习
Schody dwubiegunowe proste
winding stairs
开始学习
kręte schody
cantiliver stairs
开始学习
schody wspornikowe
timber stairs
开始学习
Schody z drewna
going
going = tread
开始学习
stopnica
RISER in PRIVATE STAIRS
Rise maximum 220mm. RISE = 150mm- 220mm.
开始学习
wysokość stopnia
H = 150mm-220mm
GOING in PRIVATE STAIRS
GOING minimum 220mm. GOING = 220mm- 300mm.
开始学习
SZEROKOŚĆ STOPNIA
intended
Private: intended to be used for only one dwelling.
开始学习
przeznaczony
assembly
Institutional and assembly: Serving a place where many people gather.
开始学习
zgromadzenie
gather
Institutional and assembly: Serving a place where many people gather.
开始学习
zbierać
headroom
Minimum headroom= 2m.
开始学习
wysokość prześwitu
Institutional and assembly stairs
Maximum rise = 180mm. Minimum going 280.(If the area of a floor of the building is less than 100m2, the going may be reduced to 250mm.)
开始学习
Instytucjonalne i zbiorowe schody
Pitch
the maximum pitch for private stair is 42°.
开始学习
kąt nachylenia
gangway for seated spectators
The maximum pitch for gangways for seated spectators is 35°.
开始学习
Przejście na siedzących widzów
escalator
开始学习
schody ruchome
stair well
开始学习
dusza schodów
fire escape stairs
开始学习
schody ewakuacyjne
dividing flights
A stair in a public building which is wider than 1800mm should be divided into flights which are not wider than 1800mm.
开始学习
podzielenie biegu
length of flights
The number of risers in a flight should be limited to 16 if a stair serves an area used as a shop or for assembly purposes.
开始学习
długość biegu
lending next to doors
at least 400mm.
开始学习
spocznik obok drzwi
cupboard
at least 400mm.
开始学习
szafka nad spocznikiem
alternating tread stair
开始学习
zmienny stopień
walkways
开始学习
chodniki
Handrails for stairs
In all buildings hadrail height should be between 900mm and 1000mm measured to the top of the handrail from the pitch line or floor.
开始学习
Poręcze na schodach
guarding
Flights and landings shoul be guarded at the sides (in dewellings) when there is a drop of more than 600mm.
开始学习
osłona / ochrona
drop
开始学习
spadek
guarding
Single family dwellings:1. Stairs, landings, ramps, edges of internal floors. H= 900mm. 2. External balconies and edges of roof. H= 1100mm.
开始学习
osłona / ochrona
suitable handrails for common stairs
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
开始学习
odpowiednie porecze dla powszechnych schodów poręcze
formula
The normal relationship between the dimensions of the rise and going is that twice the rise plus the going (2R+G) should be between 550mm and 700mm.
开始学习
wzór
2R+G = 550mm -700mm
readily
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
开始学习
łatwo
Utility stair
开始学习
schody użyteczności publicznej
external stairs
For dwellings, for external tapered stairs that are part of the buildings, the going should be a minimum of 280mm.
开始学习
schody zewnętrzne
Width of STAIRS
minimum width of 900mm. Landings should be at least the width and length of the minimum width of the fight. For buildings other than dwellings, each landing should have an unobstructed length of at least 1,200m.
开始学习
Szerokość schodów

您必须登录才能发表评论。